Published on Jul 28, 2012

Air condtioner repair Louisville | Home Performance Solutions | Call (502)749-4969

Here I show the problems with having dirty filters

Here is a video that I made on how to measure BTU
http://www.youtube.com/watch?v=YpBTlG...

If you would like more information about Home Performance Solutions you can visit our website at :

http://www.homeperformancehvac.com

or you can call us anytime at (502)749-4969

At Home Performance Solutions we offer Furnace and Air Conditioner repair, service and installation in the Metro Louisville and surrounding area.

If you are in our service area and would like for us to come out and perform a furnace or air conditioner repair or maybe you would like a furnace or air conditioner service performed we are here for you.

We are pleased to offer you a free second opinion on any furnace or air conditioner repair or a free estimate on replacing your furnace, air conditoner or heat pump.

Thank you for taking the time to view our videos and we hope to see you real soon

Comments • 35

Rennis Henry
9 k btu whoa that's lower than a large window unit puts out
Richard Close
( +Michael Brown) the wattage is one part of the equation used to determine the EER of the complete system. Notice (@6:19) that the two BTU totals are vastly different, 39k & 9k BTU's BUT THE TOTAL ENERGY required for each is differentiated by less than a 60 watt light bulb! (2630 watts vs. 2253 watts). This reveals that the unit is costing more than 4 times in energy costs (39,000/9,000=4 ). Total increased to the consumer doesn't stop there, longer run times, oil return issues, overheating of discharge valves etc etc. https://en.wikipedia.org/wiki/Seasonal_energy_efficiency_ratio
Ben Kuxhouse
the pressure temp differences make no sense, the after looks like the before, you have a clogged air filter you get low pressure, superheat, 23F coil gives you icing.
marjones69
What happened to this guy..he made great videos...he was on some next level stuff with the printouts and all that, way before the iconnect/imanifold
Kevin Knight
Great video. I've never seen the wattage measurement taken at the contactor. If you don't mind me asking, what do you personally use this measurement for? Thanks, I learn a few things from your videos and appreciate your expertise. 
Richard Close
+Michael Brown the wattage us used to determine the EER of the unit. Notice that the two 'total BTU's ' are so vastly different, 36.9K compared to 9K BUT the total power difference between the before and after is less than a 60 watt light bulb. You can't determine what a unit is costing to operate or how well its operating without knowing this information. Every GOOD manufacturer will include in their literature charts at different temps as to what the EER/SEER and watts should be, their ball parks, this example shows the system is in need of extreme attention.
David Well
What is your opinion on the more expensive air handler filters? My HVAC guy said not to use them since they put more of a load/restriction on the air handler. I have always used them for day one (ten years) and my air handler coil is very clean.  Tks
Richard Close
+David Well Depends if the installer designed the duct system to accommodate for such, if not the service man is correct. I've found most companies don't even design, nor do they know how too design ducts, they use rule of thumbs.
Christian Chan
dude i love your videos, i want all your tools men! it's almost impossible to get them in mexico :(
caridad martinez
y cxan get the filter 20 21donde puedo consegir para mi carrier esa medida cque no consigo en ningun home depot 
Keith Mylum
Great video! Thanks for sharing. You said subtract 35 degrees from your indoor temp and that should give you your evap saturation temp. I am assuming that is for a 15seer. What would it be for ten and thirteen seer? Great tip by the way! That was subtracted from room temp not return temp correct?
Eddie L.
I made a video on determinig EER, you sholud check it out. 