Northern Industrial Tool MIG 135 Wire Feed Welder Set-Up
Loading...
5,873
Loading...
Uploader Comments (metalmanworkgear)
see all
All Comments (4)
-
A very nice video with one glaring mistake. At time 8:40, the speaker said to set the regulator to "20 cubic feet per minute." Surely he meant per hour. But worse, he then proceeds to crank the regulator up to 20 L/min (the outside scale) which is equal to 42 scfh (the inside scale). Be careful, or you'll be surprised how fast your gas is exhausted.
-
20 cf a hour not a minute
-
great video
Loading...
Yes, as others have commented in the past, there is a couple mistakes regarding the level of shielding gas. You are correct, it is 20 cubic feet per hour that should be used. Thank you for pointing it out. Glad the rest of the video was useful to you.
metalmanworkgear 2 months ago