How to reproduce this experiment
The CFR project is a High Temperature Plasma Electrolysis fully based on the Tadahiko Mizuno experiment from the university of Hokkaido in Japan. This is a very in...
How to reproduce this experiment
The CFR project is a High Temperature Plasma Electrolysis fully based on the Tadahiko Mizuno experiment from the university of Hokkaido in Japan. This is a very interesting experiment and its implication can be a real breakthrough in the field of New and Clean energy source....
The enhanced CFR is composed of a 2000 mL thermostatic reaction vessel filled with 800 mL of demineralized water and Potassium Carbonate ( K2CO3 ). The electrolyte solution commonly used is 0.5 molar ( 0.5 M ).
There are three temperature probes ( K probe or PT100 ). Two probes are used for measuring the temperature of the cooling water (Temp In and Temp Out ), and one probe is used for measuring the temperature of the electrolyte solution. You need also to use a flowmeter to measure the cooling water flow.
The Cathode used is a 4 mm tungsten rod. The tungsten rod can be a pure tungsten rod or a Th-loaded tungsten TIG electrode (WT20) (with thorium oxide ThO2: 1.70% to 2.20% ) commonly used for plasma welding. The use of a Th-loaded rod increases the life of your cathod. The sputtering effect produced by the thermionic emission is lower with a Th-loaded rod than with a pure tungsten rod.
The anode used is composed of stainless steel mesh ( a grid ) maintained with stainless steel rods. If you have planned to conduct some chemical analysis, I recommend you to use a grid made with platinum or nickel . All the wires connections are made with a 1.5 mm2 copper flexible wire gained with silicon.
To avoid projections of some drops of the electrolyte solution from the CFR during the plasma ignition sequence, I recommend you to put floating balls on the surface of the liquid (hollow floating balls; pp, 20mm, 2000 PK from Cole Parmer Instrument ).
Use a DC Power Supply which is able to give about 300 V DC at 20 A ( don't use AC voltage ). The voltage is tuned with an autotransformer
Switch on the fume hood, Set the autotransformer to 0 Volt and switch on the power supply, The voltmeter (set on DC) is connected at the input of the CFR cell and the DC current clamp is connected on the positive wire, Turn the knob of the autotransformer so as to get 30V DC on the CFR cell, Let the electrolysis warm up the cell up to 50°C, At 50°C drop the voltage to 0 Volt and switch off the main power supply, Wait 30 sec to exhaust the mixture of hydrogen/oxygen, Measure the temperature ( TSinp ) of the input of the cooling water, Measure the temperature ( TSout ) of the output of the cooling water. Measure the temperature ( Tr_initial ) of the electrolyte then, immediatly, switch on the power supply, Slowly, turn the autotransformer knob so as to get 200 VDC across the cell. Start the chronometer, Note the Voltage and Current values at the permanent regime (pink glow discharge), End the run after ~3 minutes. ( set the voltage to 0 Volt and switch off the power supply ). Stop the chronometer (time). Measure the temperature ( Tr_final ) of the electrolyte, Measure the flow of the cooling water (Flow in L/min), Measure the temperature ( TEinp ) of the input of the cooling water, Measure the temperature ( TEout ) of the output of the cooling water.
Like to rate videos and let people know what you think?
Automatically share your ratings, favorites, and more on Facebook, Twitter, and Google Reader with YouTube Autoshare.
Autoshare makes certain YouTube activities public on the services you choose. Select only the services you are comfortable with - like Facebook, Twitter, or Google Reader - to let your friends know what you like on YouTube. You can turn Autoshare off at any time.
Like to share videos with friends?
Automatically share your ratings, favorites, and more on Facebook, Twitter, and Google Reader with YouTube Autoshare.
Autoshare makes certain YouTube activities public on the services you choose. Select only the services you are comfortable with - like Facebook, Twitter, or Google Reader - to let your friends know what you like on YouTube. You can turn Autoshare off at any time.
This video has been removed from your Favorites. (Undo)
Like to Favorite videos and let people know what you think?
Automatically share your ratings, favorites, and more on Facebook, Twitter, and Google Reader with YouTube Autoshare.
Autoshare makes certain YouTube activities public on the services you choose. Select only the services you are comfortable with - like Facebook, Twitter, or Google Reader - to let your friends know what you like on YouTube. You can turn Autoshare off at any time.
Question: How the hell did you get the deuterium? All im seeing hear is electrolysis, with simontaneous combustion of the resultant hydrogen. This is by no means cold fusion. I call BS
The GOVERNMENT! doesn't want yout o know about this!! They are extorting money out of the middle east by blowding up their houses and charging thems money for a new one! IF they make their own energy to lights their poppy fields they will no longer pay us money for the coal power that we build b/c they dunno hwo to build!! It's disgusting the muslims must be free of this tryanny of DICK CHAIN
real life has loads to do with Quantum Mechanics. If the laws of Quantum Mechanics didn't exist then protons and neutrons couldn't join to make atoms and without atoms then all solid mater such as my computer, the YouTube server or you and me would cease to exist
Autoshare makes certain YouTube activities public on the services you choose. Select only the services you are comfortable with - like Facebook, Twitter, or Google Reader - to let your friends know what you like on YouTube. You can turn Autoshare off at any time.