EBN Dry Cell - Efficiency Map (w/data)

Loading...

Sign in or sign up now!
13,085
Loading...
Alert icon
Sign in or sign up now!
Alert icon

Uploaded by on Aug 17, 2008

This is the efficiency data plot for the EBN 6 inch Dry Cell. (Energy Builders Network)

Plotted efficiencies for 4N4, 5N3 and 6N2 configurations.

Best MMW was 6.618 (unsustainable) in the 6N2 configuration (@ 0.267 LPM)

Best sustainable MMW was 6.174 in the 5N3 configuration (@ 1.214 LPM).

Best output was 1.569 LPM @ 5.991 MMW in the 4N4 configuration.

Data referred to in this video can be found here:
http://www.martin02.org/~lutherp/EBN_Dry_Cell_HHO_data_2008-08-17.pdf

At this time, I would like to see a 5N4 or 5N5 arrangement of this cell. You sacrifice a little bit of production for a gain in efficiency. You can make this back up by adding plates.

It is also my expectation that with a 5N configuration, the heat rise will be shallower and perhaps reduce the requirement of additional external cooling

I will be inquiring to see if it will be possible to get 4 more plates and 4 more gaskets without having to buy an entire cell.

I was not able to come to a conclusion regarding an advantage for wiring 4N4 as 3 positive with 2 negatives or 3 negatives with 2 positives. I will need to test for this again at a later date.

  • likes, 1 dislikes

Link to this comment:

Share to:

Uploader Comments (lutherp40)

  • Hi lutherp40 I would like to know if you have info on a 5N5?  I have ben working on a 4N5 (4x6) and it looks good.

  • Yes I do. See my "Gap Voltage - Between a Rock and a Hard Place" video.

  • hi luther.

    sorry took me time to get back to you but im useing name ...fuelban now... check out ....video.....

    FuelBan video 4 EMISSIVITY & Infrared Thermometers HHo Hydr

    this shows the problem luther, and when low and high temps have grater and lesser degrees of being wrong, the materials of the units have a lot to do with it to,.... check the vido luther its intresting stuff and quite enlightening....

    thanks luther

    thom.

  • I have considered the fact that that IR thermometers are not necessarily accurate, but that really wasn't the point. Every measuring device will have inaccuracies. What I needed was a device that read the same way every time i used it. (the error remained consistent each use) and could act as a point of reference to the actual temperature.

  • hi luther P40, where can i get the PDF file donwnload please luther, i would be intrested to look at it.

    thanks luther.

    thom in scotland.

  • The link should be working now.

see all

All Comments (32)

Sign In or Sign Up now to post a comment!
  • Hello! 'm from Brazil. I am trying to mount a cell but I am having difficulty level. between the plates is a blur of brown mass, and corrodes the plates between them, do not know where I am wrong can you help me (316 L stainless steel passivation) visionmachine@bol.com.br

  • @Davehho1 lol had same prob, I use a blow off top for me bubbler now, at about 30 psi it triggers a blow off valve with a rod that unlatch's the retainer clip. Seen one that used a spring to hold down the top... worked excellent.

  • just short of the water boiling is optimum temp for electrolysis. I found -nnnn+nnnn- config to work best with mine (3/4mm gaps). Also found the lower the voltage to each plate seems to produce more hydroxy.. odd so I'm running a tiny 4" cube dry cell with 11 plates 1.5 litre a min @12volt just under 15 amps.

  • Thats a very good question indeed. The link to it over in the more description is not currently working.

    I will need to investigate.