Check out our blog http://www.besafephilly.wordpress.com to learn more about SimplexGrinnell's commitment to life safety. SimplexGrinnell is certified to service Fire Alarm & Detection Systems, Sprinkler Systems, Fire Extinguishers, Suppression Systems, Emergency/Exit Lighting, Sound and Communications, and Integrated Security Applications. Thousands of organizations throughout North America choose SimplexGrinnell to test, inspect, and maintain their crucial facilities systems. Our factory−trained service technicians can support both SimplexGrinnell and non−SimplexGrinnell equipment. There's no substitution for our quality, knowledge, experience and willingness to exceed your expectations.
SimplexGrinnell's NICET certified electronic fire alarm inspector performs an elevator recall test according to NFPA 72 standards. The purpose of testing the elevator recall function of the fire alarm system is to ensure that the elevator is going to move to the exit floor of the building in the event of a fire. This is done by testing a smoke head as normal and the elevator recall is verified by ensuring that the elevator drops to the exit floor. According to NFPA 72 code, an elevator recall test should be done on an annual basis. To see additional fire alarm inspection videos check out the inspection videos tab on our blog http://www.besafephilly.wordpress.com
Contact your Philadelphia team here http://on.fb.me/BeSafePhillyFacebook for more information on how you can get your fire alarm and/or sprinkler systems tested and inspected according to NFPA code. Your Philadelphia team includes: Michael O'Donnell: 267-229-9916 or miodonnell@simplexgrinnell.com , Michael Kruszewski: 267-625-9158 or mkruszewski@simplexgrinnell.com , and John Watson: 215-316-9953 or jwatson@simplexgrinnell.com. As your SimplexGrinnell Philadelphia team, we encourage you to contact us for all of your life safety inspection needs.
Category:
Tags:
- electronic fire alarm
- elevator recall
- smoke detector
- nfpa
- simplexgrinnell
- philadelphia
- nicet
- life safety
License:
Standard YouTube License
-
4 likes, 1 dislikes
1:27
110 Testing Once Againby Voyage400918 views
7:23
Tree House Fire Alarm System Test 6by firekid1311,881 views
1:17
Elite Entrance Elevator in the London Transport Museum (accidental fire alarm activation 0:39)by harrihealey026,329 views
1:46
Fire Alarm Test NNHSby bait281,580 views
2:15
Fire alarm testby PaulBalentine5,308 views
1:18
fire alarm test at school2by renaultsimon4,036 views
7:20
School Fire Alarm 3/10/2011 11:43AM (Real Fire)by Skyscraper4461,580 views
0:06
Ringing The Alarm In The Kone EcoDisc Elevatorby nathanandrews1006,364 views
1:07
Hospital Fire Alarm Testby Farenheit40514,464 views
0:49
Wheelock fire alarm speaker/strobe test 1by Federal3t222,976 views
0:48
Who pulled the fire alarm...lolby liltiko830 views
0:55
Lower Haight Fire (2)by zmansf2,034 views
1:38
System Test 8by firealarmfan55555825 views
0:59
Gardena High School overhead catches on Fireby deumerik1,386 views
4:27
System Test 12.5: Earthquake and Fire Drillby PianoGuyUncut3,620 views
0:34
Fire Alarm Testby beckileighs1,114 views
4:24
NFPA 25 Sprinkler Backflow Preventer Inspection - SimplexGrinnell Philadelphiaby besafephilly775 views
0:52
Squirrel pulls school fire alarmby wtvttv2,451 views
2:05
Columbia Fire Sprinkler System Service and Maintenanceby ColumbiaFireInc1,066 views
- Loading more suggestions...
Link to this comment:
All Comments (0)