One helluva tight install. No stackable option?
-
I qualified on the Buderus GB125, a boiler/burner package with a Buderus-made honest-to-goodness blue flame burner. Even the non-condensing model gets 90 pct. efficiency. I figure, if you're going to go to the trouble of stocking Riello parts, might as well stock Buderus parts instead and get better efficiency.
-
What are the setting for a temp.control. They are set for, high 180, low 120 , and the differential at 15. Is this right??
-
Great system! super clean install. And nothing beats a Riello burner.! Cheers
-
wait,,,wait..who do i call????cant understand the ten comments and stickers...lmao!!
-
@Tomjr222 mass cmr says all oil lines must be incased in a non metalic sleev. some towns make you do it on over head lines too. i am an oil burner tech.
-
@Taino871 in massachusets the cmr says all oil lines have to be incased in a non metalic sleeve. i also am a oil burner tech, some towns even make you incase over head lines. i agree with the lines in the cement, but the over head lines is pushin it. i did an oil tank today and the fire captin had to come to check if we put plugs in the old tank before removel
-
great boiler, prob the best in newengland right now, esp with the logimatic and the reilo. they make a condesating boiler that gets over 91 percent. but your chiminey still can condencate at 89 percent, and what will happen is your burner will have aratic flame, the chiminey will be cold and the hot temp of the boiler flue gass will mess up the draft. its happened to me on older houses, if it happens to you, pull out baffels and that will alow hotter flue temps. thats if your chiminey isnt lined
In Massachusetts, the oil line would need to be replaced with a pre-sleeved oil line all the way back to the tank. I prefer envirotube brand. I would also recommend putting a Roth or Schutz tank in the house because if they have an underground steel oil tank, it's not a question as to if it will leak, but when. Oil contamination is very expensive to clean up. Also, what brand is the air separator? I've never seen one like that.
TomTheTechnician 1 year ago
@TomTheTechnician
The air separator is a B&G Enhancer, works very well. The vent is 3/4 but can be replaced with a bushing and standard 1/8 air vent.
Tomjr222 1 year ago
Great boiler and burner. Servicing it is going to suck though. I would have used the indirect water heater that goes under the boiler to save floor space so you could get around the boiler if you needed to replace anything in the back. Also, Buderus recommends using the oil filter you have at the oil tank with a spin-on filter with bracket at the burner with a flex line so you can open the door without disconnecting the oil line. If this was in MA, the oil line would need to be sleeved and
TomTheTechnician 1 year ago
@TomTheTechnician
I prefer side by side since i have the room, but a stackable for a closet is the wat to go.
It is not that difficult to work behind it. It looks that way on the video. You are the first one in 2 years to point out it is missing the back flow preventor, thanks i will put that on.
The oil tank is inground, there is only about 4 feet of line then goes thru the foundation
Would Ma. still require a sleeved line?
Thanks for you comments.
Tom
Tomjr222 1 year ago
Hello Tom,
Are you still happy with this Boiler? Ca nyou give me an some Idea of how much it costs?
Thanks! Tom Feely
sinsagoodmansbrother 1 year ago
@sinsagoodmansbrother
Tomjr222 1 year ago