Rheem RGRM 90% two stage furnace installation start up
Loading...
7,360
Loading...
Uploader Comments (dizziedallas)
see all
All Comments (24)
-
test
-
@dizziedallas Cool, did you make it? Just wondering for my own use.
VuVu
-
@jay11j Thank you! I does take me some time to set up the unit for proper operation! No only do I have to set up the t-stat I also have to do a state required duct pressure test a refrigerant verification test.
-
@cobitech Thank so much!!
Loading...
nice, clean install
blissJesus1 4 months ago
@blissJesus1 Thank you so much!
dizziedallas 4 months ago
How in the world did you get lucky enough to get the one furnace change out that had a straight enough galvanized flue to allow the new PVC flue to just slide inside it? I’ve been doing a ton of those 95% furnace upgrades because the tax credit and every one of them had a hundred elbows in the flue ducting.
Do you use cellular core PVC of solid core PVC? I only ask because my HVAC supplier’s only carrier cellular core for furnace venting which is not the correct PVC for flues.
ComfortAirCompany 1 year ago
@ComfortAirCompany Hey your message slip pass me!! I have been real lucky lately!! not so next week! All my jobs I use solid core PVC, I have never used cellular core.
dizziedallas 1 year ago
does this unit have enough combustion air?? im jus asking because i didn't see a vented door or a place where the unit can recieve some air... because if it isn't vented properly in another 2 years this unit will be no good... not crticizing jus asking...
vaynol81 1 year ago
@vaynol81 No problem! If you look at the upper left hand side there is a upper combustion air and there is two behind the furance @ 2:34 you can see one of two.The combustion air communicate with the attic.
dizziedallas 1 year ago