Misubishi Elevator - First Run, going down on inspection mode

Loading...

Sign in or sign up now!
10,584
Loading...
Alert icon
Sign in or sign up now!
Alert icon

Uploaded by on Jun 11, 2009

Traction motor and computer unit for a modern Mitsubishi H-GPS4 series elevator, Running at inspection speeds but is rated for 60M/min. (technician is driving car down via remote-control).

Nowadays most of the elevator components (traction motor, door driver) are running on three phase, 10KHz power at variable voltages; this is controlled by digital computer. It's called VVVF, for variable voltage and frequency. This is NOT a DC motor as I previously understood.

Input power is 220VAC single-phase, transformed up to 400 VAC before entering the system (which changes power output as needed).

Other than the sound of the ventilation fan (the computer circuit cabinet) and the occasional sound of the brakes, the only sound from the traction motor is a high frequency (10KHz) hum. There are inspection controls in the cabinet, as well as three LED digit displays displaying current floor and operation status (stop, up/down, etc). Apart from several "Mitsubishi" chips, an Intel 80386 CPU is at the core of its processing power. The motherboard equipment is not unlike a PC case or server, but there are voltage coils underneath. The motherboard will be covered by a vented panel when the car is due for service.

此短片展現的是三菱電梯智慧節能型的電梯驅動馬達,第一次運轉,平衡垂才剛剛裝上,以低速(維修人員遙控操作)向下行駛中。

幾乎所有的電梯設備都改採調頻變壓供電,包括車門驅動馬達以及捲場馬達。交流電源頻率10千赫以上,電壓由控制設備微調輸出 0V~380V 電力。機房控制箱內包括行車控制。調頻變壓系統簡稱 VVVF, 並非是直流電.

機房電力輸入採用原有單相 220V, 經過變壓器轉成 380VDC 輸入到控制設備,由電腦調整所需要的輸出。

影片中最大的噪音來自控制設備本身的散熱風扇,除了碟盤煞車偶爾作動的聲音外,並無其他可辨別的噪音。捲場機的馬達採用高頻運轉,接近無聲。

機殼內有工程人員用來直接控制電梯的開關,也可透過板子上的LED數字直接判讀車廂位置,運轉狀態。電路板的核心運算 採用 Intel 80386 晶片運作。平常是蓋起來的,跟一般PC沒有兩樣,除了下方有許多高壓變電線圈..

Manufactured in 2009.
生產年份: 2009

  • likes, 0 dislikes

Link to this comment:

Share to:

Uploader Comments (petershen1984)

  • thanks... I am not really an electrician or an elevator technician and I welcome this knowledge...

    for this elevator, the door drive is also modulated at triple-phase high frequency power :-)

see all

All Comments (2)

Sign In or Sign Up now to post a comment!
  • I'd like to note that the 10kHz frequency is not the analogue frequency to the 60Hz the motor is driven by. It means that a pulsating current of 10kHz is modulated with 0...around 10 or 100Hz or something. And that's the frequency the motor's speed depends on. :o)

    Nice video by the way, thanks a lot!