HOLA!! Just letting you know this test method was not performed correctly. You do not decant the water like was shown, the tamper drop height is supposed to be 5 mm not over an inch. The sample should not be pressed with the thumbs and should shear slightly, the sample shown did not slump or shear. The pycnometer should have a capacity of 500 ml, it looks like the one shown in this video is 1000 ml.
HOLA!! Just letting you know this test method was not performed correctly. You do not decant the water like was shown, the tamper drop height is supposed to be 5 mm not over an inch. The sample should not be pressed with the thumbs and should shear slightly, the sample shown did not slump or shear. The pycnometer should have a capacity of 500 ml, it looks like the one shown in this video is 1000 ml.
I am an ACI examiner.