@KittycatWrangler Ya don't need reservoirs with Hydro - Temp com 4Synergy (tm) Systems.
Harrisburg PA 3100 sq ft and adual compressor has the first zone = to 80% of the first compressor so it runs 12-14 minutes, and the mixing keeps heads pressures at compressors safely above any failure. no reservior, under 100/ month and just a single 1.1/2" radiant loop, con do same with any small boiler + larger boiler or staging... not just GT. and only 750 ft SERIES 1.1/4" ground loop in 54 degrees
I love this technology. I have it my house in Cooperstown, NY. It is constant, warm heat. You don't notice it going on or off. And it's LYING there in the ground. All we have to do is go fetch.
This is an awesome house by an awesome builder. I should know... it is my new house. It has wonderful experimental windows (shown in previous videos), that I never expected at the start of this project. It all just sort of evolved. It is my own private "Woodstock". Eebuilder, Tom has researched it all since age 15, he is now 40 plus a little.
What is the initial cost difference from an HVAC system? Also a total price of this system would be awesome so I can get an idea of costs to expect.
ReggyRay289 1 year ago
@KittycatWrangler Ya don't need reservoirs with Hydro - Temp com 4Synergy (tm) Systems.
Harrisburg PA 3100 sq ft and adual compressor has the first zone = to 80% of the first compressor so it runs 12-14 minutes, and the mixing keeps heads pressures at compressors safely above any failure. no reservior, under 100/ month and just a single 1.1/2" radiant loop, con do same with any small boiler + larger boiler or staging... not just GT. and only 750 ft SERIES 1.1/4" ground loop in 54 degrees
GTPro1980 1 year ago
great system
freemanscott63 1 year ago
With the exception of all of that CPVC, it looks like a sanitary plumbing job. Good luck.
KittycatWrangler 1 year ago
I love this technology. I have it my house in Cooperstown, NY. It is constant, warm heat. You don't notice it going on or off. And it's LYING there in the ground. All we have to do is go fetch.
rvbarnesboy 2 years ago
CPVC>>>> Too bad for you other than that it looks nice..
plumrdude 2 years ago
Is that CPVC on the manifold?
thatguybikes 2 years ago
Your job would have been a lot easier and simpler with a B&D HSS Buffer tank and a non-pressurized flow center.
xxxcre10xxx 2 years ago
Is the PVC you used here sched. 40?
thatguybikes 2 years ago
This is an awesome house by an awesome builder. I should know... it is my new house. It has wonderful experimental windows (shown in previous videos), that I never expected at the start of this project. It all just sort of evolved. It is my own private "Woodstock". Eebuilder, Tom has researched it all since age 15, he is now 40 plus a little.
I am the lucky recipient of all that knowledge.
mortonssalt 2 years ago