HVAC - Relocating Air Conditioners

Loading...

Sign in or sign up now!
Alert icon
Upgrade to the latest Flash Player for improved playback performance. Upgrade now or more info.
8,272
Loading...
Alert icon
Sign in or sign up now!
Alert icon

Uploaded by on Jun 7, 2009

This is a follow-up to the More Boo-Boo's video. Refrigerant lines and electrical have already been roughed in the trench. Now it's time to reset the beasts.

Tight quarters. Don't bother telling me about clearances and code violations. I've done that dance with Lennox and they'll warranty my work. Building inspectors have no problem with my stuff because it looks neat and the electrical side totally conforms with building codes. Well... almost.

Regardless, I will not be called back on this one. The kick is up... and it's GOOD! Stick a fork in this job... it's done.

  • likes, 1 dislikes

Link to this comment:

Share to:

Uploader Comments (PutSome5tankOnIt)

  • 87y87ty

  • Thank you for that.

  • Nice work. You seem to come across quite a few systems to relocate. Do you dig trenches yourself or have the homeowner worry about that?

  • It's usually a landscaping crew that does the digging. One guy with a jackhammer (shovel bit) and two with shovels. They'll pound out an 18" deep x 12" wide x 25 foot long trench in 15 minutes.

  • Rubatex, aka armaflex, is 3/4" nominal wall. The insulation is 3/4" thick. What size do y'all use in your neck of the woods?

  • It's 3" Corex. The plumbing aisle at Home Depot is where you'll find it. Comes as perforated or non-perforated. Intended for use as drainage piping.

see all

All Comments (8)

Sign In or Sign Up now to post a comment!
  • your brazing pretty shitty your bending prettty shitty your pipe on the other end wasnt insulated... and why did you ? use a 3/8 coupling?

  • your welding is rather crappy why isnt the pipe insulated? on the other end? and also... your bending is pretty shitty

  • Nice to see there's still some pros out there. Hey I was wondering what size armaflex do you all use out in CA? Looks like 2 possibly 3 inch.

  • nice job on the underground what is the pipe called that the lineset is ran threw ,I use 3inch sched 40 pvc and it can be a pain in the ass.