Carrier Infinity 2 stage gas furnace
Loading...
2,487
Loading...
Uploader Comments (TexasAcSpecialist)
see all
All Comments (9)
-
first of all you have a appliance whip to your furnace ...ALL WRONG.... second your coil should be after the furnace for your app. dont get me wrong great piece of equipment just installed wrong also why not spent a few dollars more and go 90% and go concentric vent out the roof ??????????????????]
-
Your Flex is maxed out LOL
Loading...
transition between furnance and evap coil Coil should not butt up against furnance unless coil and furnance is same size I can see where you blanked off the coil. Read install instructions
gsummers2007 1 year ago
@gsummers2007 Carrier coil instructions read if coil is larger than furnace and air flow is from left to right to coil shall be flush at bottom and sticking up on top. If air flow is from right to left then coil shall be even at top and sticking out at bottom. The reason is to make sure proper air flow across all circuits of the coil. Once again do not bash someones install unless you know what you are talking about..thanks
TexasAcSpecialist 1 year ago
Also the high voltage wire entering furnace is done by cold in my area. Codes is other areas are different. I had this inspected. So once again if you post that someone installed something incorrectly you should be sure you are accurate in your assessment.
TexasAcSpecialist 1 year ago
Coil is after furnace because airflow is from left to right. So the coil is after the furnace. Second I am in Texas homes here are not set up for 90 percent furnaces. Because we do not need them. So smart guy before you say someone installed something wrong be sure to know what you are talking about first.
TexasAcSpecialist 1 year ago