Facebook's new energy efficient data center

Loading...

Sign in or sign up now!
Alert icon
Upgrade to the latest Flash Player for improved playback performance. Upgrade now or more info.
30,851
Loading...
Alert icon
Sign in or sign up now!
Alert icon

Uploaded by on Apr 28, 2011

Cloud technologies power some of Internet's most well-known sites—Picasa, Gmail, Facebook and Zynga, just to name a few—and cloud companies are striving to make the computer processing behind these sites as energy efficient as possible. With that in mind, Facebook, Dell, HP, Rackspace, Skype, Zynga and others have teamed together to form the Open Compute Project to share best practices for making more energy efficient and economical data centers.

To kick-start the project, Facebook unveiled its innovative new data center and contributed the specifications and designs to Open Compute. "Cloud companies are working hard to become more and more energy efficient...[and] this is a big step forward today in having computing be more and more green," explains Graham Weston, Chairman of Rackspace.

A small team of Facebook engineers has been working on the project for two years. They custom designed the software, servers and data center from the ground up.

One of the most significant features of the facility was that Facebook eliminated the centralized UPS system found in most data centers. "In a typical data center, you're taking utility voltage, you're transforming it, you're bringing it into the data center and you're distributing it to your servers," explains Tom Furlong, Director of Site Operations at Facebook. "There are some intermediary steps there with a UPS system and with energy transformations that occur that cost you money and energy—between about 11% and 17%. In our case, you do the same thing from the utility, but you distribute it straight to the rack, and you do not have that energy transformation at a UPS or at a PDU level. You get very efficient energy to the actual server. The server itself is then taking that energy and making useful work out of it."

To regulate temperature in the facility, Facebook utilizes an evaporative cooling system. Outside air comes into the facility through a set of dampers and proceeds into a succession of stages where the air is mixed, filtered and cooled before being sent down into the data center itself.

"The system is always looking at [the conditions] coming in", says Furlong, "and then it's trying to decide, 'what is it that I want to present to the servers? Do I need to add moisture to [the air]? How much of the warm air do I add back into it?'" The upper temperature threshold for the center is set for 80.6 degrees Fahrenheit, but it will likely be raised to 85 degrees, as the servers have proven capable of tolerating higher temperatures than had originally been thought.

The servers used in the data center are unique as well. They are "vanity free"—no extra plastic and significantly fewer parts than traditional servers. And, by thoughtful placing of the memory, CPU and other parts, they are engineered to be easier to cool.

Now that these plans and specifications have been released as part of the Open Compute Project, the goal is for other companies to benefit from and contribute to them. "Open source, crowd sourcing, Wikipedia—these are all capitalizing on, or enabled by, the same force," explains Weston, "which is that when things are open, there's more innovation around them."

More info:

Facebook announcement: http://tinyurl.com/4x67au9
Open Compute Project web site: http://opencompute.org/

Link to this comment:

Share to:

Top Comments

  • Although this guy is a director and what is known of directors is that they should be concerned with management issues only, he is aware of al technical stuff behind the scenes of what he's running. All directors and managers should be knowledgible of what they manage so that they can be efficient managers.

  • this guy knows what he is talking about ... right man in the right place

see all

All Comments (20)

Sign In or Sign Up now to post a comment!
  • uhhhhhhh is it allowed to steal teh cablez and run like fuck?

  • I wonder if evaporative cooling works in humid climates like Texas or Georgia? I have never seen a swamp cooler in the south. We use a chiller plant to cool our servers. We probably spend twice what they spend in power.

  • "you can feel its about 72 degrees right now" 

  • Fuck Facebook

  • fuck you facebook you are a son of bitch !! sperrts user grund los !!! stirb facebook !!

  • esto es lo que quieren tumbar los de Anonymous; que tontos

Loading...

Alert icon
0 / 00Unsaved Playlist Return to active list
    1. Your queue is empty. Add videos to your queue using this button:
      or sign in to load a different list.
    Loading...Loading...Saving...
    • Clear all videos from this list
    • Learn more