Zachary was diagnosed with croup and then RSV... It's been a fun, stressful time, but he seems to be getting better. He should only need this treatment for 2 weeks. He doesn't like the mask, but calms down and smiles when we sing Itsy Bitsy Spider to him.

What is a nebulizer?

A nebulizer is a machine that uses compressed air to deliver asthma medicine as wet aerosol, a mist that can be inhaled. Nebulizers are most often used for children younger than 5, people who have difficulty using inhalers, and those with severe asthma. Nebulizers are also used by people with chronic lung diseases, such as emphysema. The most common medications used in a nebulizer are bronchodilators (such as albuterol) to help open up air passages and inhaled steroids.

Nebulizers have three main parts: a cup that holds the medication, a mouthpiece or mask attached to a "T"-shaped part, and a thin, plastic tube that connects the mouthpiece to the compressor. There are home and hospital models of nebulizers, as well as portable units. The portable machines run on batteries or can be plugged into your car's cigarette lighter.

How to use a nebulizer

Read the equipment instructions completely before using your nebulizer, because directions vary from one manufacturer to another.

The medication solution that you will use in an aerosol machine may come in a multi-dose bottle with a dropper, or in a small plastic vial.

Steps for using a nebulizer:

Wash your hands prior to preparing each nebulizer treatment, and make sure the equipment is clean.


If using a multi-dose bottle of medicine, use the dropper to put the correct amount of medication into the cup with saline solution. If your medicine is in single-use vials, twist open the top of the plastic vial and then squeeze the contents into the nebulizer cup.


Connect the mouthpiece to the T-shaped part and then fasten this unit to the cup, or fasten the mask to the cup. It is recommended that children older than 2 years old use a mouthpiece because it will deliver more medication than the mask.


Connect the nebulizer tubing to the port on the compressor.


Hold the nebulizer in an upright position to prevent spilling.


While sitting in a comfortable, upright position place the mouthpiece between your teeth and close your lips around it. Or, put on the mask, making sure it fits well so mist won't go into your eyes.


Turn the compressor on and check the nebulizer for misting. When using a finger valve, cover the air hole to force the air into the nebulizer. If you are not using a finger valve, the nebulizer will mist continually.


Gently breathe out. As the mist starts, inhale slowly and deeply through your mouth, taking over three to five seconds for each breath, while keeping your finger over the valve hole.


At the end of a deep breath, uncover the finger valve hole to stop the mist.


Hold your breath for up to 10 seconds before exhaling. This allows the medication time to deposit in the airway.


Continue until the medicine is gone from the cup (about five minutes).


Occasionally tapping the side of the nebulizer helps the solution drop to where it can be misted. Treatment is finished when all the medication has been used from the container. The nebulizer will most likely begin sputtering when it is empty.


Store the medication as directed.

How to clean a nebulizer

Clean the nebulizer regularly to keep the equipment from clogging and to help it last longer. Cleaning also helps prevent germs that can cause infection. Follow the manufacturer's instructions for cleaning and storage. Not all nebulizer parts are dishwasher safe.

After each use:

Remove the mask or mouthpiece and T-shaped part from the cup. Remove the tubing and set it aside. The tubing should not be washed or rinsed.


Rinse the mask or mouthpiece and T-shaped part in warm, running water for 30 seconds. Use distilled or sterile water for rinsing, if possible.


Shake off excess water and air dry on a clean cloth or paper towel.


Put the mask or mouthpiece and T-shaped part, cup, and tubing back together, and connect the device to the compressor. Run the machine for 10 to 20 seconds to dry the inside of the nebulizer.


Disconnect the tubing from the compressor. Make sure the nebulizer is dry before storing the nebulizer in a sealed plastic bag.


Place a cover over the compressor.

Category:

People & Blogs

Tags:

License:

Standard YouTube License

  • likes, 8 dislikes

All Comments

Adding comments has been disabled for this video.
0 / 00Unsaved Playlist Return to active list
    1. Your queue is empty. Add videos to your queue using this button:
      or sign in to load a different list.
    Loading...Loading...Saving...
    • Clear all videos from this list
    • Learn more