To restore or reset the EB4-1U unit to its factory default values.
Prior to performing the reset or restore you must Set the unit in standy by mode by having the main power switch to off position and the two power supply module switches to on postion
STEPS:
1. sET two Power Supply module switches to ON position
2. Set the main power switch to off
3. Press and hold down the Alarm Reset Button for 10 seconds
4. Power LED will blink during this second period.
When all values have been restored, the LED will stop blink and turn off
5. Now, turn on the power switch to start the unit.
Power cycling the unit or turning off and on the power doesn't enact a reset / restore.