Compression/Flexure testing machine for Cement/Dimension Stone/Concrete prism

Loading...

Sign in or sign up now!
Alert icon
Upgrade to the latest Flash Player for improved playback performance. Upgrade now or more info.
1,564
Loading...
Alert icon
Sign in or sign up now!
Alert icon

Uploaded by on Nov 11, 2010

WHY Series computer controlled Electromechanical compression testing machine is mainly used to determine of the compressive flexural strength of cement/concrete/stone.

Space adjusting, & test processes could be controlled by the software and the test result could be transferred to the software in the computer for further analysis. It is the most advanced series in compression testing machines. It is widely used in different engineering areas, quality control department, universities and institutes as well as other areas and works for the mechanical performance analysis of architecture, building materials.

These frames comply with national and international standards (GB, ISO, ASTM, etc) of ordinarily building materials mechanical performance testing requirement to compression tests, such as ISO679 BS EN 196-1,ASTM C880.

Features:

•Fully computer controlled testing process.
•Stable and reliable high intensity structure load frame.
•Real time display software will provide accurate track of testing process.
•Powerful multifunctional control software will provide more testing methods and standards.
•Overload protection will secure operators.
•Safe and reliable software interface and control. The software will lock the buttons during test proceed; It is very easy to prevent mistake operation during the test stage which will cause damage to the testing machine.
•Easy and fast to edit customized test reports in EXCEL format.

ISO 679: Cement -- Test methods -- Determination of strength
BS EN 196-1: Methods of testing cement. Determination of strength
ASTM C880 / C880M: Standard Test Method for Flexural Strength of Dimension Stone
EN12390-5 BS 1881:118, ASTM C78, C293, ASHTO T97: Testing hardened concrete. Flexural strength of test specimens

  • likes, 0 dislikes

Link to this comment:

Share to:
see all

All Comments (0)

Sign In or Sign Up now to post a comment!
Loading...

Alert icon
0 / 00Unsaved Playlist Return to active list
    1. Your queue is empty. Add videos to your queue using this button:
      or sign in to load a different list.
    Loading...Loading...Saving...
    • Clear all videos from this list
    • Learn more