-
Honders liked 3 weeks ago
Andrea Rossi's 'E-cat' nuclear reactor: a video FAQ
In January 2011 Andrea Rossi demonstrated a device that purported to develop 10 kW of power from a nuclear reaction. This video discusses its credi...
-
ABS Sensor Diagnostics, Troubleshooting and Repair
http://www.wellsve.com/ Anti-lock brake system diagnostics and repair. 2002 Honda Accord ABS code 15-1 and PCM code P0135. Step by Step wheel speed...
-
-
Honders liked 2 months ago
Zach Wahls Speaks About Family
Zach Wahls, a 19-year-old University of Iowa student spoke about the strength of his family during a public forum on House Joint Resolution 6 in th...
-
The Answer to all our energy "problems": Cold Fusion
Cold Fusion, although virtually ignored by mainstream academic research, has continued underground through the efforts of brave and dedicated scien...
-
Total Knee Replacement Surgery Part 2 - Update 2011
Actual High Definition video of a Total Knee Replacement surgical procedure. This is an updated version of the original #1 video of its kind in th...
-
Low Energy Nuclear Revolution
An engineer and a scientist make a public presentation of a controversial
machine. It is a reactor which, apparently, produces a low energy nuclear...
-
-
Honders liked 1 year ago
House Tour Pt2
Hey friends and family, enjoy pt2.
-
House Tour Pt1
Hey friends and family, enjoy.
-
-
Honders commented 1 year ago
Power House Micro Hydro 20 KW Pumps as Turbine Motor as Generator
This Micro Hydro installation uses Pumps as Turbines and 3 phase Motors as single phase Generators. (yes you can!) There is 210 feet of head (92 PS...
@councilglasses
Motor / generator is rated 30 HP. Magnetic pickup / hall device RPM signal fed back to butterfly valve control motor. Keeps frequency to within a couple of hertz.
Rob
Power House Micro Hydro 20 KW Pumps as Turbine Motor as Generator
This Micro Hydro installation uses Pumps as Turbines and 3 phase Motors as single phase Generators. (yes you can!) There is 210 feet of head (92 PS...
166,953 views
Honders said:
@HungryGreeny Yes, the load controllers act more rapidly to keep the voltage in check. The frequency feedback loop is slower acting but keeps the long term stability of the frequency in check. Grid connected generators are automatically stabilized by the grid and don't need these controls.
Power House Micro Hydro 20 KW Pumps as Turbine Motor as Generator
This Micro Hydro installation uses Pumps as Turbines and 3 phase Motors as single phase Generators. (yes you can!) There is 210 feet of head (92 PS...
166,953 views
Honders said:
@HungryGreeny ,
It has a frequency feedback loop. If frequency drifts up the valve closes some, if frequency goes down the water valve is opened very slowly.
Power House Micro Hydro 20 KW Pumps as Turbine Motor as Generator
This Micro Hydro installation uses Pumps as Turbines and 3 phase Motors as single phase Generators. (yes you can!) There is 210 feet of head (92 PS...
166,953 views
Honders said:
Sorry, no such thing as a perpetual motion machine. But check out LENR CANR on google. Pons and Fleischman discovered it in 1989, now Rossi and Focardi appear to have a practical working device!
Happy Hydro
Rob
Power House Micro Hydro 20 KW Pumps as Turbine Motor as Generator
This Micro Hydro installation uses Pumps as Turbines and 3 phase Motors as single phase Generators. (yes you can!) There is 210 feet of head (92 PS...
166,953 views
Honders said:
@Spicyperson9123
You are right, fusion, hot fusion at that. Check out what is happening in cold fusion, google LENR SPAWAR.
Power House Micro Hydro 20 KW Pumps as Turbine Motor as Generator
This Micro Hydro installation uses Pumps as Turbines and 3 phase Motors as single phase Generators. (yes you can!) There is 210 feet of head (92 PS...
166,953 views
Honders said:
@bashiryu
I have water coming from upstream. The nuclear fission in the sun put it there (rain). I'm just extracting a small % of the energy that the sun put into the water by raising it up.
If I were to try to pump it back up I would lose about half the energy in the water at each spin around t...
Power House Micro Hydro 20 KW Pumps as Turbine Motor as Generator
This Micro Hydro installation uses Pumps as Turbines and 3 phase Motors as single phase Generators. (yes you can!) There is 210 feet of head (92 PS...
166,953 views
Honders said:
@bashiryu
The flywheel stores energy, 10,000 Watts for 1 second, or 5000 W for 2 seconds etc.
This helps to start up heavy loads like electric motors which draw a large initial startup current (power) and then, once up to speed, the power requirement drops off.
See: EnergyIndependence-Rob.Blogsp...
Power House Micro Hydro 20 KW Pumps as Turbine Motor as Generator
This Micro Hydro installation uses Pumps as Turbines and 3 phase Motors as single phase Generators. (yes you can!) There is 210 feet of head (92 PS...
166,953 views
Honders said:
@dadigitechman
Two 1500 watt 240V water heater elements in series for total of 3000W @480V.
These water heating elements are immersed in the penstock. The controller only turns them on proportionally to the amount of over voltage. No over voltage no wasted energy in dump load.
Power House Micro Hydro 20 KW Pumps as Turbine Motor as Generator
This Micro Hydro installation uses Pumps as Turbines and 3 phase Motors as single phase Generators. (yes you can!) There is 210 feet of head (92 PS...
166,953 views
Honders said:
@socertiesDB9
Look for pumps that have enclosed impellers. See: EnergyIndependence-Rob.Blogspot.com for more information.
+ View allshow less