  • HOLA!! Just letting you know this test method was not performed correctly. You do not decant the water like was shown, the tamper drop height is supposed to be 5 mm not over an inch. The sample should not be pressed with the thumbs and should shear slightly, the sample shown did not slump or shear. The pycnometer should have a capacity of 500 ml, it looks like the one shown in this video is 1000 ml.