@rhett443 No; they are 2099-series pulls. The 4251 does not have the hourglass logo; it just says "SIMPLEX". It also has a small plastic knob near the handle, and the frame around the handle is thicker and more rounded. The color of the 4251 is also more of a bright red-orange and the 2099 is a dull red.
@rhett443 Those appear to be 2099-9754 because the word "Simplex" is not all capital letters.All the 4251 type pull stations have the word "SIMPLEX" in all capital letters on the bottom
the ademco fire panels made below 2006 do temporal pulse. The Ademco panel does not do a very good job of it. (it skips beats or makes them longer/shorter.
because there used to be a simplex 4100. i used to have that but i parted it out and sold it. There is no reason to replace the pulls all they are are switches
main system board was HELLLA confused. The troubles would not go away, it would set the fire alarm off, and it would randomly dial. all the wiering was ok and cards were replaced on the panel but nothing worked. so it was replaced.
@FiReAlArMtEcH2600 They did that same thing at the middle school near my house! They had a Simplex 4100U voice-evacuation panel (replacing an ancient zoned Edwards system), but it used addressable T-bar pulls and TrueAlarm smoke detectors. But it suffered the same problems as you mentioned, so the 4100U system was completely replaced with a Notifier NFS2-640 system, but they managed to get the existing TrueAlert speaker/strobes to work on it.
What coding option is that?
TechnologysEdge 2 weeks ago
It took the control panel awhile to activate. Where those set to tone?
TssCman123 1 year ago
Those sound like EHS-DL1's
Farenheit4051 1 year ago
What does opening the pull station with the key like you do to trip the system do as opposed to simply pulling it??
peakster753 1 year ago
Are the pulls 4251-20's?
rhett443 1 year ago
@rhett443 i dont remember. they are conventional
FiReAlArMtEcH2600 1 year ago
Comment removed
Farenheit4051 1 year ago
Comment removed
Farenheit4051 1 year ago
This has been flagged as spam show
@rhett443 No; they are 2099-series pulls. The 4251 does not have the hourglass logo; it just says "SIMPLEX". It also has a small plastic knob near the handle, and the frame around the handle is thicker and more rounded. The color of the 4251 is also more of a bright red-orange and the 2099 is a dull red.
Farenheit4051 1 year ago
@rhett443 No. Notice how the pull has the newer Simplex logo on it. The 4251-20s have older logos.
msj191961 10 months ago
@rhett443 Those appear to be 2099-9754 because the word "Simplex" is not all capital letters.All the 4251 type pull stations have the word "SIMPLEX" in all capital letters on the bottom
WheelockAlarms 8 months ago
how did you get the job to do the bell testing
alarm610 2 years ago
@alarm610 its called working for a company lol
FiReAlArMtEcH2600 1 year ago
Those are MTs? They sound just like truealerts lol.
ProwerBot 2 years ago
@ProwerBot MT-24-VFR
FiReAlArMtEcH2600 1 year ago
@ProwerBot No the are Wheelock EHS Horn Strobes.
whelenvortexr4 7 months ago
yeahhhhh....
sorry i like the dot dot dot...
it is fun
FiReAlArMtEcH2600 2 years ago
i do it a lot. run a business...
FiReAlArMtEcH2600 2 years ago
hopefully the system got replaced with wheelocks
whelenvortexr4 1 year ago
it sounds like a simplex trualert..
Firelitestar5210 2 years ago
Wheelock MT-24-VFR
FiReAlArMtEcH2600 2 years ago
oh lol, well they sound almost the same...
Firelitestar5210 2 years ago
yeah. actually all the peizos inside of them are made by the same company.. i think
FiReAlArMtEcH2600 2 years ago
well that might be interesting..
Firelitestar5210 2 years ago
huh?
FiReAlArMtEcH2600 2 years ago
That is an interesting code that the panel is set to what is it?
Gb755c 2 years ago
the ademco fire panels made below 2006 do temporal pulse. The Ademco panel does not do a very good job of it. (it skips beats or makes them longer/shorter.
FiReAlArMtEcH2600 2 years ago
nice shoes, btw where were u yesturday???
QueenLaRevkah 2 years ago
cabin
these are schools near there. in eastern washington
not in bellevue/seattle area.
FiReAlArMtEcH2600 2 years ago
Nice bell test man what are the alarms
jradms 2 years ago
Wheelock MT-24-VFR
FiReAlArMtEcH2600 2 years ago
what is the panel it's gotta be a simplex panel
jradms 2 years ago
no it is an ADEMCO 250FBP
FiReAlArMtEcH2600 2 years ago
so why are there simplex pulls? =\
Simplex24 2 years ago
because there used to be a simplex 4100. i used to have that but i parted it out and sold it. There is no reason to replace the pulls all they are are switches
FiReAlArMtEcH2600 2 years ago
ah. What was wrong with the 4100?
Simplex24 2 years ago
main system board was HELLLA confused. The troubles would not go away, it would set the fire alarm off, and it would randomly dial. all the wiering was ok and cards were replaced on the panel but nothing worked. so it was replaced.
FiReAlArMtEcH2600 2 years ago
Thats simplex for ye.What did the system get replaced by
whelenvortexr4 1 year ago
@FiReAlArMtEcH2600 They did that same thing at the middle school near my house! They had a Simplex 4100U voice-evacuation panel (replacing an ancient zoned Edwards system), but it used addressable T-bar pulls and TrueAlarm smoke detectors. But it suffered the same problems as you mentioned, so the 4100U system was completely replaced with a Notifier NFS2-640 system, but they managed to get the existing TrueAlert speaker/strobes to work on it.
wileyk209zback 3 months ago