AND you can only load a 15amp breaker to 80% witch is 12amps or 12 devices, 1amp per devices, not including switch's and your at 14. nice
dino4825 2 weeks ago
Hey Louie,
You forgot to mention the receptacle spacing requirement per code requirments.
Install receptacle no more than 6'-0" from door openings, then add receptacles no more than 12'-0" apart.
Remember, all walls measuring 2'-0" or more require a receptacle.
And by the way, you forgot to add closet lighting which is also required. Check code requirements before laying out receptacles.