This is one of the reasons, why so many americans companies moving out of seas, the lack of safety regulations, the company I work for has been without an accident close to 15 yrs. thanks to the safety comitee than always put pressure to the owners on the safety issues.
I've been in IM for 25+ years as a mechanic, supervisor and manager. I've been in many shops in the USA that have machines that run with no safety switches or devices working. This is not a third world problem.
The shop I work in now had at least 13 documented safety switches bypassed 2 years ago when I started here as maintenance manager. I began fixing them immediately. A month after I started, we had an amputation accident due to a bypassed safety switch.
If you idiots new what that miolding machine can do to the human bidy., they would'nt be cyling with the door opened, what is this video about anyway,how stupid some companies can be?
Looks like he's having to close the door somewhat to getthe IMM to cycle. But it sure doesn't have to stay closed forit to cycle. Yikes! And it's an Engel, double yikes.
What a bunch of idiots!
ALRULZ1965 8 months ago
Did you guys buy that machine from South Korea? There's hangul writting on the side.
Afrocanuk 1 year ago
This is one of the reasons, why so many americans companies moving out of seas, the lack of safety regulations, the company I work for has been without an accident close to 15 yrs. thanks to the safety comitee than always put pressure to the owners on the safety issues.
rolin910 2 years ago
He is running in semi auto, and apparently it only requires a momentary gate closed signal to actuate
bkmcclarty 3 years ago
I've been in IM for 25+ years as a mechanic, supervisor and manager. I've been in many shops in the USA that have machines that run with no safety switches or devices working. This is not a third world problem.
The shop I work in now had at least 13 documented safety switches bypassed 2 years ago when I started here as maintenance manager. I began fixing them immediately. A month after I started, we had an amputation accident due to a bypassed safety switch.
bkmcclarty 3 years ago
this another proof for me that operators are stupids i am a set up man in injection so i don t like operators lol people without ambitions
patsymtl 3 years ago
If you idiots new what that miolding machine can do to the human bidy., they would'nt be cyling with the door opened, what is this video about anyway,how stupid some companies can be?
tommee10533 3 years ago
Looks like he's having to close the door somewhat to getthe IMM to cycle. But it sure doesn't have to stay closed forit to cycle. Yikes! And it's an Engel, double yikes.
TCLightning 4 years ago
incredible !!!!
tophe38 4 years ago
Why is the clamp on this IMM closing with the operator door open! What other safety systems have been disabled I wonder. Not smart.
roscoe426 4 years ago