i think stan meyer was using pulsed dc at a resonant frequency at a higher voltage to produce the same results using less current (milliamperes=1000times smaller than 1 ampere). If your gonna put 6 amps DC through that thing you might as well us electrolysis instead.
you need to have your tube annealed in an (argon?) atmosphere and it will be more productive if you "condition it with increasing voltages in increments of 5 giving it a break and then adding another five untill you hit 30. after you do all of that, thats when your cell will hit peak efficiency
In this video I was using pulsed DC but got the same gas output as with just straight DC. I was using about 6 amps. When I can get the same output with 1 or less amps I will give instructions on how to build what I do it with.
ok nice one i reall want to make my 2nd cell i have 1 video on me cell at the moment but its crap just (+)(-) that it i am going to try a nutral cell in a min kk
Yes, this is the way. Congratulations. Please post more of your videos. We will be honoured to participate on your sucesses and failures, cause this is the right path. We dont want straight amperage UNEFFICIENT conventional electrolisys, we want Stan Meyer zero point EFFICIENT super-electrolisys, right? Let the truth be spoken NOW. Hugh!
(VIC)= Voltage Intensifier Circuit. This is a step up coil in series with 2 inductors and a fast switching diode. I am winding a step up transformer with 200 turns of 24 Gauge on a 1.5 inch ferrite toroid core and 1800 turns of 36 Gauge for the secondary, with tap points at 600,900,1200,1500 and 1800 turn points so I can try different voltages to the cell. The chokes will be bifilar wound on a .75 inch ferrite rod 7 inches long. this VIC should minimize the amps and give me plenty of volts.
Email me at Voltrolysis(@)hotmail(dot)com, and I will send you links to the VIC diagram, online parts list and links to Stan Meyer instruction videos.
Voltage intensifier circuit = transformer choke coils diode. Volt, note primary coil should be at resonance when on, check that with a volt meter in parallel with the primary side of coil, look for top volt reading. check out waterfuelcell or stanleymeyerscom
VIC = Voltage Intensifier Circuit. This is a step up transformer in series with 2 inductors to restrict amps and let voltage take over to perform the work.
At this point it does appear to put out the same. BUT!.. I have yet to put this pulse system in series with Stan Meyers Voltage Intensifier Circuit (VIC). Winding that now. I have a Liter Per Minute (LPM) gas flow meter and will use that and an amp meter to determine gas outputs form different configerations
i think stan meyer was using pulsed dc at a resonant frequency at a higher voltage to produce the same results using less current (milliamperes=1000times smaller than 1 ampere). If your gonna put 6 amps DC through that thing you might as well us electrolysis instead.
UniversalExpanse 10 months ago
Sooo, How's the WFC thing going?
bartley440 2 years ago
Any big progress on producing HHO?
bartley440 2 years ago
a stan meyer setup. rofl you fucking jockeys.
get a clue.
sephiroth671 2 years ago
What's the frecuency you'r using (cicles per second).
For what i saw you have a very good production right there. How many liters per minute?
RaulGreenPower 3 years ago
How much energy does it take to run the pulse?
The777truth 3 years ago
sorry amps condition with amps
vdubdipr 3 years ago
you need to have your tube annealed in an (argon?) atmosphere and it will be more productive if you "condition it with increasing voltages in increments of 5 giving it a break and then adding another five untill you hit 30. after you do all of that, thats when your cell will hit peak efficiency
vdubdipr 3 years ago
wot is this
DellInspiron56798723 4 years ago
please send link for details and diag
jeremusic 4 years ago
Those who will be able to split 1 kg of water using less than 4.4 kWh will be efficient.
-1kWh=860kcal
-H2 combustion energy = 33811kcal/kg
- from 8.9368 kg of water you get 1kg of H and 7.9368 kg O.
So,in 1kg of H2O we have 4.4 kWh of H.
ghandrei 4 years ago
make a video on how to make one
pitbike2006 4 years ago
In this video I was using pulsed DC but got the same gas output as with just straight DC. I was using about 6 amps. When I can get the same output with 1 or less amps I will give instructions on how to build what I do it with.
VOLTROLYSIS 4 years ago
ok nice one i reall want to make my 2nd cell i have 1 video on me cell at the moment but its crap just (+)(-) that it i am going to try a nutral cell in a min kk
pitbike2006 4 years ago
how do you make one
plz write back!
unidudedx 4 years ago
Yes, this is the way. Congratulations. Please post more of your videos. We will be honoured to participate on your sucesses and failures, cause this is the right path. We dont want straight amperage UNEFFICIENT conventional electrolisys, we want Stan Meyer zero point EFFICIENT super-electrolisys, right? Let the truth be spoken NOW. Hugh!
Blueskyh2o 4 years ago
(VIC)= Voltage Intensifier Circuit. This is a step up coil in series with 2 inductors and a fast switching diode. I am winding a step up transformer with 200 turns of 24 Gauge on a 1.5 inch ferrite toroid core and 1800 turns of 36 Gauge for the secondary, with tap points at 600,900,1200,1500 and 1800 turn points so I can try different voltages to the cell. The chokes will be bifilar wound on a .75 inch ferrite rod 7 inches long. this VIC should minimize the amps and give me plenty of volts.
VOLTROLYSIS 4 years ago
nice going. let us know your progress
motofox69 4 years ago
He meant that with his pulse setup going he got about the same results as he did with straight DC. I'm still going for the pulse setup though.
brianempson 4 years ago
Yes... same output... but that should change.
Email me at Voltrolysis(@)hotmail(dot)com, and I will send you links to the VIC diagram, online parts list and links to Stan Meyer instruction videos.
VOLTROLYSIS 4 years ago
@VOLTROLYSIS
the email u mentioned isnt working anymore?
ShinobiLB400 1 year ago
Voltage intensifier circuit = transformer choke coils diode. Volt, note primary coil should be at resonance when on, check that with a volt meter in parallel with the primary side of coil, look for top volt reading. check out waterfuelcell or stanleymeyerscom
HydroCars 4 years ago
This is so great, I think I am going to dump my HHO generator and make another. Makes you rethink all this work. Thanks
pwmpower 4 years ago
Please define "VIC".
ising4jesus 4 years ago
VIC = Voltage Intensifier Circuit. This is a step up transformer in series with 2 inductors to restrict amps and let voltage take over to perform the work.
VOLTROLYSIS 4 years ago
You said the pulse has been the same as straight DC.
What frequencies & pulse widths have you tried? All of the documentation states that these are crucial to producing the larger amounts of HHO.
ising4jesus 4 years ago
At this point it does appear to put out the same. BUT!.. I have yet to put this pulse system in series with Stan Meyers Voltage Intensifier Circuit (VIC). Winding that now. I have a Liter Per Minute (LPM) gas flow meter and will use that and an amp meter to determine gas outputs form different configerations
VOLTROLYSIS 4 years ago
Cool.
stancruse 4 years ago